Product | | Description | Availability |
|
LOAD CENTER FILLER PLATE
EATON
BRFP
|
BR FILLER PLATE
CIRCUIT BREAKER SPACE; POLE SPACE 1 INCH; USED ON BR SERIES LOADCENTER
Show all: Load Center Accessories
Spec Sheet | More Details
|
47
|
|
LOAD CENTER MAIN LUG KIT
EATON
BRL200
|
200A MAIN LUG KIT
MAIN LUG; 1 AWG TO 300 KCMIL CONDUCTOR; CONDUCTOR MATERIAL ALUMINUM/COPPER; USED ON BR SERIES LOADCENTER; BR MODEL
Show all: Load Center Accessories
Spec Sheet | More Details
|
2
|
|
LOAD CENTER MAIN AND SUB-FEED LUG BLOCK
EATON
BRSF125
|
SUB FEED LUG BLOCK 125A 2P
125 AMPERE; 2 POLE; (2) 1 INCH MAXIMUM SPACE(S); CONDUCTOR SIZE 8 AWG; 2/0 AWG; CONDUCTOR MATERIAL ALUMINUM/COPPER; QUANTITY 1; USED ON BR SERIES LOADCENTER
Show all: Load Center Accessories
Spec Sheet | More Details
|
7
|
|
LOAD CENTER GROUND BAR KIT
EATON
GBK1020
|
10 CIRCUIT+1-2/0 LUG GROUND BAR
LENGTH 5.34 INCH; CONDUCTOR MATERIAL ALUMINUM/COPPER; 1 TERMINAL ((1) 6 TO 2/0 AWG), 10 TERMINAL ((3) 14 TO 10 AWG OR (1) 14 TO 4 AWG); USED ON BR SERIES LOADCENTER
Show all: Load Center Accessories
Spec Sheet | More Details
|
3
|
|
MAIN LUG LOAD CENTER
EATON
BR24L70RP
|
1PH 70A MLO N3R LOADCENTER
MAIN LUG; 120/240 VAC; 70 AMPERE; 4 MAXIMUM CIRCUIT(S); (2) 1 INCH MAXIMUM SPACE(S); INTERRUPTING RATING 10000 AMPERE; INSULATED/BONDABLE NEUTRAL; TIN PLATED ALUMINUM BUS MATERIAL; BOTTOM/TOP FEED LOCATION; MAIN WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); NEMA 3R, OUTDOOR, RAIN PROOF ENCLOSURE; ENCLOSURE SIZE DESIGNATION 5R; SIZE 4-1/2 INCH W X 3 INCH D X 9-7/16 INCH H; APPROVAL UL 50, UL 67, UL 489, UL 869; BR MODEL; APPLICABLE STANDARD NEC
Show all: Single Phase Main Lug Load Centers
Spec Sheet | More Details
|
3
|
|
LOAD CENTER GROUND BAR KIT
EATON
GBK5
|
5 CIRCUIT GROUND BAR
LENGTH 2.54 INCH; CONDUCTOR MATERIAL ALUMINUM/COPPER; 5 TERMINAL ((3) 14 TO 10 AWG OR (1) 14 TO 4 AWG); USED ON TYPE CH LOADCENTER; GBK MODEL
Show all: Load Center Accessories
Spec Sheet | More Details
|
1
|
|
LOAD CENTER GROUND BAR KIT
EATON
GBK10
|
10 CIRCUIT GROUND BAR
LENGTH 4.29 INCH; CONDUCTOR MATERIAL ALUMINUM/COPPER; 10 TERMINAL ((3) 14 TO 10 AWG OR (1) 14 TO 4 AWG); USED ON TYPE CH LOADCENTER; GBK MODEL
Show all: Load Center Accessories
Spec Sheet | More Details
|
3
|
|
LOAD CENTER GROUND BAR KIT
EATON
GBK2120
|
21 CIRCUIT+1-2/0 LUG GROUND BAR
LENGTH 9.19 INCH; CONDUCTOR MATERIAL ALUMINUM/COPPER; 21 TERMINAL ((3) 14 TO 10 AWG OR (1) 14 TO 4 AWG), 1 TERMINAL ((1) 6 TO 2/0 AWG); USED ON TYPE CH LOADCENTER
Show all: Load Center Accessories
Spec Sheet | More Details
|
3
|
|
LOAD CENTER FILLER PLATE
EATON
CHFP
|
CH FILLER PLATE
CIRCUIT BREAKER SPACE; POLE SPACE 3/4 INCH; USED ON TYPE CH LOADCENTER; CH MODEL
Show all: Load Center Accessories
Spec Sheet | More Details
|
|
|
CONVERTIBLE LOAD CENTER
EATON
BR1224N125
|
1PH 125A N1 LOADCENTER
CONVERTIBLE MAIN; 120/240 VAC; 125 AMPERE; 24 MAXIMUM CIRCUIT(S); (12) 1 INCH MAXIMUM SPACE(S); BR MAIN BREAKER; INTERRUPTING RATING 10000/22000/25000 AMPERE; INSULATED/BONDABLE NEUTRAL; TIN PLATED ALUMINUM BUS MATERIAL; BACK FEED LOCATION; MAIN WIRE SIZE 4 TO 2/0 AWG, 2 AWG TO 300 KCMIL (ALUMINUM/COPPER, MAIN BREAKER); 6 TO 2/0 AWG (ALUMINUM/COPPER, MAIN LUG); NEMA 1, INDOOR ENCLOSURE; FLUSH/SURFACE COVER; ENCLOSURE SIZE DESIGNATION B2; SIZE 14-5/16 INCH W X 3-7/8 INCH D X 18-3/4 INCH H; APPROVAL UL 50, UL 67, UL 489, UL 869; BR MODEL; APPLICABLE STANDARD NEC
Show all: Single Phase Convertible Load Centers
Spec Sheet | More Details
|
2
|
|
MAIN LUG LOAD CENTER
EATON
BR612L125RP
|
1PH 125A MLO N3R LOADCENTER
MAIN LUG; 120/240 VAC; 125 AMPERE; 12 MAXIMUM CIRCUIT(S); (6) 1 INCH MAXIMUM SPACE(S); INTERRUPTING RATING 10000 AMPERE; INSULATED/BONDABLE NEUTRAL; TIN PLATED ALUMINUM BUS MATERIAL; BOTTOM/TOP FEED LOCATION; MAIN WIRE SIZE 14 TO 1 AWG (ALUMINUM/COPPER); NEMA 3R, OUTDOOR, RAIN PROOF ENCLOSURE; ENCLOSURE SIZE DESIGNATION 7R; SIZE 11 INCH W X 3-9/16 INCH D X 13 INCH H; APPROVAL UL 50, UL 67, UL 489, UL 869; BR MODEL; APPLICABLE STANDARD NEC
Show all: Single Phase Main Lug Load Centers
Spec Sheet | More Details
|
2
|
|
MAIN LUG LOAD CENTER
EATON
BR816L125RP
|
1PH 125A MLO N3R LOADCENTER
MAIN LUG; 120/240 VAC; 125 AMPERE; 16 MAXIMUM CIRCUIT(S); (8) 1 INCH MAXIMUM SPACE(S); INTERRUPTING RATING 10000 AMPERE; INSULATED/BONDABLE NEUTRAL; TIN PLATED ALUMINUM BUS MATERIAL; BOTTOM/TOP FEED LOCATION; MAIN WIRE SIZE 14 TO 1 AWG (ALUMINUM/COPPER); NEMA 3R, OUTDOOR, RAIN PROOF ENCLOSURE; ENCLOSURE SIZE DESIGNATION 7R; SIZE 11 INCH W X 3-9/16 INCH D X 13 INCH H; APPROVAL UL 50, UL 67, UL 489, UL 869; BR MODEL; APPLICABLE STANDARD NEC
Show all: Single Phase Main Lug Load Centers
Spec Sheet | More Details
|
2
|
|
LOAD CENTER
EATON
3BR3L100R
|
3PH 100A MLO N3R LOADCENTER
MAIN LUG; 208 VAC STAR/120/240 VAC VOLTAGE RATING; 100 AMPERE CURRENT RATING; 3 MAXIMUM CIRCUIT(S); 3 MAXIMUM SPACE(S); INSULATED/BONDABLE NEUTRAL; ALUMINUM BUS MATERIAL; TOP/BOTTOM FEED LOCATION; MAIN WIRE SIZE 14 TO 1/0 AWG; NEMA 3R, OUTDOOR ENCLOSURE; FLUSH/SURFACE COVER; ENCLOSURE SIZE DESIGNATION 9R; SIZE 6.5 INCH W X 4 INCH D X 14.25 INCH H; BR MODEL
Show all: Three Phase Main Lug Load Centers
Spec Sheet | More Details
|
1
|
|
CONVERTIBLE LOAD CENTER
EATON
BR3040N200
|
1PH 200A CONV MAIN N1 LOADCENTER
CONVERTIBLE MAIN; 120/240 VAC; 200 AMPERE; 40 MAXIMUM CIRCUIT(S); (30) 1 INCH MAXIMUM SPACE(S); BW MAIN BREAKER; INTERRUPTING RATING 10000/22000/25000 AMPERE; INSULATED/BONDABLE NEUTRAL; TIN PLATED ALUMINUM BUS MATERIAL; BACK FEED LOCATION; MAIN WIRE SIZE 2 AWG TO 300 KCMIL (ALUMINUM/COPPER, MAIN BREAKER), 1 AWG TO 300 KCMIL (ALUMINUM/COPPER, MAIN LUG); NEMA 1, INDOOR ENCLOSURE; FLUSH/SURFACE COVER; ENCLOSURE SIZE DESIGNATION G1; SIZE 14-5/16 INCH W X 3-7/8 INCH D X 34-1/8 INCH H; APPROVAL UL 50, UL 67, UL 489, UL 869; BR MODEL; APPLICABLE STANDARD NEC
Show all: Single Phase Convertible Load Centers
Spec Sheet | More Details
|
2
|
|
CONVERTIBLE LOAD CENTER
EATON
BR1224N125R
|
1PH 125A N3R LOADCENTER
CONVERTIBLE MAIN; 120/240 VAC; 125 AMPERE; 24 MAXIMUM CIRCUIT(S); (12) 1 INCH MAXIMUM SPACE(S); BR MAIN BREAKER; INTERRUPTING RATING 10000/22000/25000 AMPERE; INSULATED/BONDABLE NEUTRAL; TIN PLATED ALUMINUM BUS MATERIAL; BACK FEED LOCATION; MAIN WIRE SIZE 4 TO 2/0 AWG, 2 AWG TO 300 KCMIL (ALUMINUM/COPPER, MAIN BREAKER); 6 TO 2/0 AWG (ALUMINUM/COPPER, MAIN LUG); NEMA 3R, OUTDOOR, RAIN PROOF ENCLOSURE; ENCLOSURE SIZE DESIGNATION B2R; SIZE 14-5/16 INCH W X 5-3/16 INCH D X 18-3/4 INCH H; APPROVAL UL 50, UL 67, UL 489, UL 869; BR MODEL; APPLICABLE STANDARD NEC
Show all: Single Phase Convertible Load Centers
Spec Sheet | More Details
|
3
|